Time Since Transition Randomize
The Time Since Transition (TST) Randomize Property is used to initialize the TST values at the start of a model run. This feature randomly assigns a TST value between a Minimum and Maximum Initial TST Value for each Simulation Cell.
The fields for the Time Since Transition Randomize property are:
Iteration (optional)
The Iteration to use this value for. If unspecified, values will be used for all iterations. If not all iterations are specified, each iteration will used the closest specified previous iteration value.
Primary Stratum (optional)
The Primary Stratum for which the TST Randomization record applies. If left blank then the TST Randomization record applies to all primary strata.
Secondary Stratum (optional)
The Secondary Stratum for which the TST Randomization record applies. If left blank then the Randomization record applies to all secondary strata.
Tertiary Stratum (optional)
The Tertiary Stratum for which the TST Randomization record applies. If left blank then the TST Randomization record applies to all tertiary strata.
Transition Group (optional)
The Transition Group for which initial TST values are being randomized. If left blank, then the Randomization record applies to all transition groups.
State Class (optional)
The State Class for which initial TST values are being randomized. If left blank, then the Randomization record applies to all state classes.
Initial TST Min (optional)
The minimum value to be assigned as the TST for any Simulation Cells in the Stratum specified.
Initial TST Max
The maximum value to be assigned as the TST for any Simulation Cells in the Stratum specified. Values will be randomized between the min and max.